Checking the magnetization of the spheres and flinders bar
Dockside test before starting the adjustment
It is of paramount importance, among all the physical checks of the compass and binnacle to completely be sure that the spheres and Flinders Bar are not magnetized since if they are, the adjustment could be almost impossible and maybe, even the adjuster will not realize the reason why.
The procedure is very easy and it is as follows:
Testing Residual Magnetism in Spheres
1/Regarding the spheres, you have to move the spheres as close to the compass as possible and slowly rotate each sphere separately.
Any appreciable deflection ( 2º or more) of the compass needles resulting from this rotation indicates residual magnetism in the spheres.
This test may be made with the ship on any steady heading when alongside.
Flinders Bar Check & Procedure
2/Regarding the Flinders Bar the magnetization check is preferably made with the ship on steady east or west compass heading.
To make this check, take note of the compass heading with the Flinders Bar in the holder invert the Flinders bar in the holder and again take note of the compass heading.
Any appreciable difference (2º or more) between these two observed readings indicates residual magnetism in the Flinders Bar.
Spheres or Flinders bars which show signs of such residual magnetism should be anneal.i.e, heated to a dull red and allowed to cool slowly or in the case of the spheres, to strike one against to the other.