Checking the Magnetization of the Spheres and Flinders Bar
MAGNETISM

Checking the magnetization of the spheres and flinders bar

Dockside test before starting the adjustment

CHECKING-THE-MAGNETIZATION-OF-THE-SPHERES-AND-FLINDERS-BAR

It is of paramount importance, among all the physical checks of the compass and binnacle to completely be sure that the spheres and Flinders Bar are not magnetized since if they are, the adjustment could be almost impossible and maybe, even the adjuster will not realize the reason why.

The procedure is very easy and it is as follows:

Testing Residual Magnetism in Spheres

1/Regarding the spheres, you have to move the spheres as close to the compass as possible and slowly rotate each sphere separately.

Any appreciable deflection ( 2º or more) of the compass needles resulting from this rotation indicates residual magnetism in the spheres.

This test may be made with the ship on any steady heading when alongside.

ANNEAL

Flinders Bar Check & Procedure

2/Regarding the Flinders Bar the magnetization check is preferably made with the ship on steady east or west compass heading.

To make this check, take note of the compass heading with the Flinders Bar in the holder invert the Flinders bar in the holder and again take note of the compass heading.

Any appreciable difference (2º or more) between these two observed readings indicates residual magnetism in the Flinders Bar.

Spheres or Flinders bars which show signs of such residual magnetism should be anneal.i.e, heated to a dull red and allowed to cool slowly or in the case of the spheres, to strike one against to the other.

Nautical Compass logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.